| ====== Moxa IO device through Modbus ====== | ====== Moxa IO device through Modbus ====== | ||
| - | TERRA 4D comes with a Modbus plugin which allows integration of different types of Modbus devices. | + | TERRA 4D comes with a Modbus plugin which allows integration of different types of Modbus |
| ===== Supported features: ===== | ===== Supported features: ===== | ||
| Line 8: | Line 8: | ||
| ===== Installation instructions: | ===== Installation instructions: | ||
| + | === Webbrowser: === | ||
| + | * Connect the Moxa device to Ethernet and open the browser | ||
| + | * Connect to address 192.168.127.254 which is normally the default IP address of the Moxa devices | ||
| + | * Main things to configure: Password, Security/ | ||
| + | * alternatively you can use IOxpress software | ||
| === Moxa IOxpress software: === | === Moxa IOxpress software: === | ||
| - | | + | |
| - | | + | |
| - | | + | |
| + | * on the Device Library page you find in the Deployment combobox the device actions, like up- and download of configuration files | ||
| + | * on the Configuration Library page you can change all settings and store it to a local file | ||
| === TERRA 4D Configurator: | === TERRA 4D Configurator: | ||
| - | | + | |
| - | Input: | + | |
| - | | + | |
| - | | + | |
| - | Output: | + | |
| - | | + | |
| - | | + | |
| + | * Input register (e.g. for PWM counter): | ||
| + | * create a IO device of type Modbus and select SubType "Input register" | ||
| + | * IP port: 502, Server address: 0, Start address: 17, Input number: 0...N | ||
| + | * Analog Input: | ||
| + | * create a IO device of type Modbus and select SubType " | ||
| + | * IP port: 502, Server address: 0, Start address: 520, Input number: 0...N | ||
| + | * Configure low/high threshold depending on application to generate events when reading goes outside the expected range. | ||
| ===== Other hints ===== | ===== Other hints ===== | ||
| + | * Within the device web page, in the main menu, within User-Defined Modbus Addressing, select Analog Inputs, Digital Input/ | ||
| + | * Make sure " | ||
| + | * Within the table all the addresses of the available data points are listed. E.g. "AI Scaling Value (Float)" | ||
| + | * Within Terra4D use " | ||
| + | * [[https:// | ||